Mechanical Maintenance; Hyprotect™ Breakaway Arm Mount; Breakaway Fasteners - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

m
eCHanICal
CAUTION
Before checking the internal mechanisms of the operator, turn off all power switches.
The StrongArmPark DC mechanical maintenance is not in depth or difficult, but should be performed on a
routine basis. The operator chassis is zinc plated, but some environments may speed corrosion of this plating.
Schedule regular maintenance and look for the following:
Assess that the drive belt has the proper tension. Check for drive belt wear. Fraying edges or missing
teeth indicate that the drive belt needs to be replaced.
Check for signs of rust. If any areas of rust are found, reduce the spread of corrosion by treating the
areas with a rust inhibitor.
Replace worn-out batteries.
On the StrongArmPark DC 14 spring assembly, apply grease to zerk fitting and upper rod end.
HyProtect™ Breakaway Arm Mount
The breakaway arm fasteners may need to be replaced from time to time. Use the following table to gauge
which fasteners should be used.
NOTE: Each bolt is secured with an aluminum lock washer and nylon hex nut. Torque to 15 in-lb.
10 ft or shorter
10 ft or shorter
10 ft or longer
10 ft or longer
NOTE: *Be aware, when using two steel bolts, that the arm may bend before the bolts break which voids the
Warranty.
www.hysecurity.com
© 2017
m
aIntenanCe

Breakaway Fasteners

2 nylon bolts
1 nylon bolt
1 steel bolt
2 steel bolts*
Low wind
High wind
Low wind
High wind
General Maintenance
MX3650-01 Rev. D
73