HySecurity StrongArmPark DC Programming And Operations Manual page 38

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

Installer Menu
0 = Reopen if center loop triggers
CR 0 REVERSE
Center Loop
1 = Pause only
CB 0 (OFF)
0 = Normal operation of Free Exit
CLD Disable ELD
1 = Disable Free Exit
CP 0 (OFF)
0 = Immediate closure
1 = Provides addt'l open time
CLD Counts PBO
EB 0 (OFF)
0 = Normal operation of Free Exit
ELD Backoff
1 = Back off close function
RL 1 0 DISABLED
0 = Disabled
Relay 1 Logic
1 to 38 available
RL 2 0 CLOSE LIMI
0 = Disabled
Relay 2 Logic
0 = Disabled
RL 3 0 DISABLED
thru
RL 10 0 DISABLED
1 to 38 available
Relay Logic
TL 2 (45 SECS)
2 = 45 second delay
Open Time Alert
0 = 0s delay
1 = 15s
3 = 75s
4 = 105s
5 = 135s
28
MX3650-01 Rev. D
Table 4: Installer Menu
Setting Options
StrongArmPark DC Programming & Operations
Menu Tasks & Explanations
The default allows the barrier arm to reopen if
the Center Loop detector is triggered during
closure of the barrier arm. A setting of 1 causes
the barrier arm to only pause when triggered.
Closure begins as soon as the loop is clear
again.
Setting 1 allows an CLD input to disable the
Free Exit Detector (ELD) until the barrier arm
is fully closed. Used in bi-directional traffic
situations.
The default allows the Center Loop Detector
when triggered and released, to close the
barrier arm immediately. The optional setting
of 1 designates that the Smart DC Controller
remember an additional open command if the
open input is activated a second time while
the barrier arm remains open. (For example, to
prevent a vehicle from being stranded).
The default allows normal latch open operation
of the Free Exit detector. The optional setting
of 1, creates an automatic close function if a
vehicle triggers and then backs off the Free
Exit Loop detector.
Configures the function of the User 1 output
relay. It has the capacity to switch both AC and
DC loads and can be used for high voltage
and/or high current loads. Connect devices
directly to the top of the relay: COM and either
NO and/or NC contacts.
Multiple logic function options exist. See User
Relays - Programming Procedure on page
39.
Relay 2 configures the function of the User 2
output relay, which is an electronic relay with
the capacity for switching a DC load only.
NOTE: In the StrongArmPark DC, it is
recommended to use the User 2 Relay for
connection to the LED arm lighting.
Similar to Relay 1 Logic.
This menu item only appears if the #8 User
Relay function has been selected. It adjusts the
time delay before activation of the User Relay
function.
SDC Wire
Connections
Center Loop
COM or connection
to Hy5x detector
Center Loop
COM or connection
to Hy5x detector
Center Loop
COM or connection
to Hy5x detector
Free Exit Loop
COM or connection
to Hy5x detector
COM
User 1 Relay
COM
User 2 Relay
COM
User 3 through 10
Relay
User Relay