Dc Battery Replacement - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

dC B
atterY
HySecurity provides a one year warranty from the date of shipment for all batteries supplied with the
StrongArmPark DC operator.
Display indicators of a low battery include:
LOW BATTERY or DEAD BATTERY appears on the Smart DC Controller display which may or may not
be indicative of normal discharge.
ALERT 18 CHANGE BATTERY appears on the
Smart DC Controller display. The operator emits
an audible chirp every minute to indicate a problem exists.
AP (#) AC LOSS appears on the Smart DC Controller display. Gate operation is affected by AC power
loss depending on customer preferences and the configuration set by the installer in the AP (#) AC
LOSS User Menu.
Symptoms of a low battery may include:
Gate remains locked in the open position
Gate remains locked in the closed position
Gate opens five seconds after AC power loss and locks open
CAUTION
Before replacing the batteries, turn off all power switches. Use only AGM batteries as replacements (8Ah -
MX002008). The batteries supplied in the StrongArmPark DC operator are state-of-the-art AGM batteries. Do
NOT use flooded cell batteries as damage may occur to the unit. Wear protective clothing while working with
batteries.
www.hysecurity.com
© 2017
r
eplaCement
General Maintenance
MX3650-01 Rev. D