Install Hy5B Vehicle Detectors - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

Install Hy5B Vehicle Detectors

Install one Hy5B detector at a time. Each vehicle detector socket is labeled.
1. Turn power OFF in control box.
2. Insert the squared-off end of the plastic standoff
through the hole in the Hy5B detector.
NOTE: The plastic standoff "squared-off end" does not fit
into the mounting holes of the control box. Double check
the orientation of squared-off ends.
3. To minimize excessive flexing, keep each Hy5B
perpendicular to the control board as you plug it
into the Hy5B socket.
4. Secure the Hy5B by inserting each plastic
standoff into the chassis.
5. Place the two wires from the loop into the push terminals of the Hy5B. For ease of installation, the wire
gauge should be 20 - 14 AWG. Refer to Vehicle Loop Sets on page 46.
NOTE: If you have more Hy5B detectors, repeat the steps 2 through 4 for each additional Hy5B detector.
Loop Type
Installer Menu Loops Smart DC
Exit Loop
Inside Reversing Loop
Outside Reversing Loop
Reset/Shadow/Center
5. Turn power to the gate operator back ON.
6. The Hy5B indicator light flashes red and the following appears.
46
MX3650-01 Rev. D
Plastic standoff
Hy5B vehicle detector
ELD
EXIT LOOP
ILD
INSIDE
OBSTRUCTION
OLD
OUTSIDE
OBSTRUCTION
SLD/CLD
CENTER LOOP
Smart Touch 7-segment
Display
InIt
StrongArmPark DC Programming & Operations
SmartDC Control Box
LED Activity
OFF
Hy5A mode
GREEN
PULSING Heart beat
RED
ON
Call Mode
View display
for more
information:
RED
FLASHING
Initializing
or
Faulty loop
Vehicle Loop Sets
Loops Smart Touch
FREE EXIT
INSIDE OBSTR
OUTSIDE OBSTR
SHADOW / RESET
STC (OLED) and Smart DC Displays
INITIALIZING
Smart Touch Control Box
Power toggle switch
Power switches
Turn off both the DC and AC switches.
LED Display Status
Indicates
Condition & Resolution
Emulation mode. Some Hy5B features are
unavailable.
Normal operation.
Status indicates loop activation in process.
If initializing, wait until initialization is
complete.
If flashing during loop operation, take
following steps:
1. Check loop wiring. See Test the Vehicle
Loop on page 45.
2. Replace loop.
3. If loop is not at issue, swap out
Hy5B vehicle detector with a known
operational Hy5B.
4. If necessary, replace Hy5B.
Description
Opens a fully-closed gate.
Connects to the inside reversing loop.
Connects to the outside reversing loop.
Prevents a gate from starting open or closed when a
vehicle is in the path of the gate.