User Menu
BF 0 (OFF)
0 = off
1 = warning buzzer on
Warn Before Operate
throughout Gate travel
2 = warning buzzer on for 2
seconds of Gate travel
FA 0 (OFF)
0 = off
1 = on
Forced Open Alert
DA 0 (OFF)
0 = off (standard)
1 = on (detailed)
Drift Close Alert
PE 0 (OFF)
0 = off
1 = on
Photo Eye Alignment
CL 0 
0 = Display
1 = Set Clock
Set Clock
5
LD 5
0 through 9
LCD Contrast
LG 0 (OFF)
0 = OFF
VIEW EVENT LOG
1 = On
www.hysecurity.com
© 2017
Table 3: User Menu
Setting Options
Controls the warn-before-operate buzzer and can
be configured three ways:
Set to 0: Buzzer is disabled. The buzzer will still
beep if alerts, faults, errors, or entrapment occur.
Set to 1: Buzzer beeps for 3 seconds before gate
moves and continues through entire length of
travel.
Set to 2: Buzzer beeps for 3s before gate moves
and continues for 2s of travel.
Intended for highly secure facilities.
Set to 1, the operator sounds the 3-second "warn
before operate" buzzer alarm and initiates a
closure if the gate is forced open and the closed
limit switch disengages. The motor starts to secure
the gate. If the gate does not fully close within 4s,
the motor turns off and the buzzer sounds for 30
seconds. The display shows ALERT 1 - FORCED
OPEN.
Set to 1, the operator sounds the 3-second "warn
before operate" buzzer alarm and initiates an
open command if the gate is forced, or drifts, off
the open limit switch. The motor starts to reopen
the gate. The motor runs for a maximum of 4s
and, if the gate is not fully open at the end of this
period, the buzzer sounds for 10s. The display
shows ALERT 2 - DRIFT CLOSED.
Set to 1, the operator serves as an aide in photo
eye transmitter/receiver alignment. The buzzer
chirps once when the emitter and receiver are
not aligned. When the emitter and receiver are
aligned, the buzzer chirps twice. If they go out of
alignment again, the buzzer will chirp once. The
Alignment Mode is reset with a close-limit input or
by pressing the Reset button.
NOTE: If the operator doesn't run when the
power switch is initially turned ON, check the
alignment of the photo eye and all the photo eye
connections.
To adjust the hour, minute, day, or month to a
different time zone, select 1. Once the clock is set,
the display returns to the 0 setting.
This feature is useful to read historic operational
data, which can be accessed with a computer via
the USB or RS-232 port.
Adjusts the contrast of the display. Available
settings from low contrast 0 to 9 high contrast,
with a factory default setting of 5.
NOTE: While the Operator Status Displays are
scrolling, you also have the ability to adjust the
contrast by pressing the PREV and NEXT buttons.
View the Event Log using the gate operator
keypad and display. For more information, refer to
Access the Event Log through the User Menu on
page 67.
Display & Menu Options
Menu Tasks & Explanations
SDC Wire Connections
Not applicable (N/A)
N/A
N/A
EYE Open
EYE Close
EYE COM
N/A
N/A
N/A
MX3650-01 Rev. D