Basic Operator Panel 20 (BOP20)

Product brief
The Basic Operator Panel 20 (BOP20) is a basic operator panel with six keys and a display
unit with background lighting. The BOP20 can be plugged onto the SINAMICS Control Unit
(e.g. CU310, CU320) and operated.
Operation is only possible from FW 2.4.
The following functions are possible using BOP20
● Entering parameters
● Display of operating modes, parameters, alarms and faults
● Powering-up/powering-down while commissioning
Further information: See 'Parameterizing using the BOP20 (Basic Operator Panel 20)'
chapter
2.3.1

Important functions via BOP20

Description
Using the BOP20, the following functions can be executed via parameters that support you
when handling projects:
● Restoring the factory settings
● Copy RAM to ROM
● Identification via LED
● Acknowledge error
Restoring the factory settings
The factory setting of the complete device can be established in the drive object CU.
● p0009 = 30
● p0976 = 1
Copy RAM to ROM
In the drive object CU you can initiate that all parameters are saved in the non-volatile
memory (CompactFlash card):
● Press the P key for 3 seconds,
● p0009 = 0
● p0977 = 1