Temperature Sensor Connections For Sinamics Components - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning

2.13 Temperature sensor connections for SINAMICS components

Position tracking
The position tracking can also be activated for a 2-pole resolver. Note that when switched
off, the resolver may not be moved more than half an encoder revolution (pole width). The
activation and configuration of position tracking must be performed in the expert list– see
documentation on position tracking.
EPOS - absolute encoder adjustment
If the 2-pole resolver is used as an absolute encoder for basic positioning (EPOS), the
absolute encoder adjustment must be performed via the expert list.
To do this, the reference point coordinate p2599 is set to the value corresponding to the
mechanical system and the adjustment requested with p2507=2.
The data is then saved by copying from RAM to ROM.
2.13
Temperature sensor connections for SINAMICS components
The following table provides an overview of the components with temperature sensor
connections available for the SINAMICS drive system.
Table 2-19
Temperature sensor connections for SINAMICS components
Module
SMC10/SMC20
SMC30
CU310
104
Interface
Pin
X520 (sub D)
13
25
X520 (sub D)
1
Temperature
8
channel 2
Only from Order No. 6SL3055-0AA00-5CA2 and Firmware 2.5 SP1
2)
X531 (terminal)
3
Temperature
4
channel 1
X120 (terminal)
4
Temperature
5
channel 2
This is the only temperature channel for Order No. 6SL3040-0LA00-0AA0 and FW 2.5 SP1 as
1)
well as all CU310 with FW 2.4.
For Order No. 6SL3040-0LA00-0AA1, this is the second temperature channel (T2), which can be
used as single channel dependent on the parameterization or in combination with the first
temperature channel (T1, refer to X23).
X23 (sub D)
1
Temperature
8
channel 1
Signal name
+Temp
- Temp
+Temp
2)
- Temp
2)
- Temp
+Temp
+Temp
1)
- Temp
1)
+Temp
2)
- Temp
2)
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
Technical specifications
Motor temperature measurement
KTY84-1C130 (KTY+) or
KTY84-1C130 (KTY-)
Temperature sensor connection
KTY84-1C130/PTC
Motor temperature measurement
KTY84-1C130 (KTY+) or
KTY84-1C130 (KTY-)
Temperature sensor connection
KTY84-1C130/PTC
Motor temperature measurement
KTY84-1C130 (KTY-)
Temperature sensor connection
KTY84-1C130/PTC
KTY or PTC input
Ground for KTY or PTC
KTY or PTC input
Ground for KTY or PTC