Diagnosis
3.2 Diagnostics via STARTER
Figure 3-7
Note
Please refer to the online help for more information about parameterizing and operation.
Features
● Measuring functions
134
"Measuring function" initial screen
– Current controller setpoint change (downstream of the current setpoint filter)
– Current controller reference frequency response (downstream of the current setpoint
filter)
– Speed controller setpoint change (downstream of the speed setpoint filter)
– Speed controller disturbance step change (fault downstream of the current setpoint
filter)
– Speed controller reference frequency response (downstream of the speed setpoint
filter)
– Speed controller reference frequency response (upstream of the speed setpoint filter)
– Speed controller interference frequency response (fault downstream of the current
setpoint filter)
– Speed controller path (excitation downstream of current setpoint filter)
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
Commissioning