Commissioning the motor with STARTER
1. Selecting the motor type
Figure 2-15
2. Enter motor data
Table 2-15
p0305
p0311
p0315
p0316
p0322
Commissioning
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
You can select a standard motor from the list of motors or you can enter the motor data
yourself if third-party motors are used. The number of parallel primary sections (p0306)
must be entered.
Motor screen in STARTER
The following motor data can be entered for third-party motors.
Motor data
Parameter
Rated motor current
Motor rated velocity
Motor pole pair width
Motor force constant
Motor velocity, maximum
2.10 Commissioning linear motors (servo)
Description
Commissioning
Remark
-
-
-
-
-