Copy RAM to ROM
You can use this function to save volatile Control Unit data to the non-volatile CompactFlash
card. This ensures that the data is still available after the 24 V Control Unit supply has been
switched off.
This function can be activated as follows:
● Extras -> Setting -> Download -> Activate "Copy from RAM to ROM"
● Right-click Drive unit -> Target system -> Copy from RAM to ROM
● Drive unit grayed out -> "Copy from RAM to ROM" button
Download to target device
You can use this function to load the current STARTER project to the Control Unit. The data
is loaded to the working memory of the Control Unit. A reset is then triggered.
This function can be activated as follows:
● Right-click Drive unit -> Target system -> Load to target system
● Drive unit grayed out -> "Load to target system" button
● "ONLINE/OFFLINE comparison" screen -> "Load to PG/PC" button
● Project to all drive units simultaneously:
Load to PG/PC
You can use this function to load the current Control Unit project to STARTER.
This function can be activated as follows:
● Right-click Drive unit -> Target system -> Load to PG/PC
● Drive unit grayed out -> "Load to PG" button
● "ONLINE/OFFLINE comparison" screen -> "Load to PG" button
Restoring the factory settings
You can use this function to set all the parameters in the working memory of the Control Unit
to the factory settings. To ensure that the data on the CompactFlash card is also reset to the
factory settings, choose the "Copy from RAM to ROM" function.
This function can be activated as follows:
● Right-click Drive unit -> Target system -> Restore factory settings
● Drive unit grayed out -> "Restore factory settings" button
For more information about STARTER, see Getting Started.
Commissioning
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
This means that every time data is loaded to the target system by choosing "Load project
to target system", the data is stored in the non-volatile memory.
"Load project to target system" button, menu Project -> Load to target system