Drive-Cliq Hub Module Dmc20; Diagnostics Via Starter - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnosis

3.2 Diagnostics via STARTER

3.1.20

DRIVE-CLiQ Hub Module DMC20

Table 3-22
DRIVE-CLiQ Hub Module DMC20 – description of the LEDs
LED
Color
READY
-
Green
Orange
Red
Green/
red
Green/
orange
or
Red/
orange
3.2
Diagnostics via STARTER
Description
The diagnostic functions support commissioning and service personnel during
commissioning, troubleshooting, diagnostics and service activities.
General information
Prerequisites: Online operation of STARTER.
The following diagnostic functions are available in STARTER:
● Specifying signals with the ramp-function generator
● Signal recording with the trace function
● Analyzing the control response with the measuring function
● Outputting voltage signals for external measuring devices via test sockets
128
State
OFF
Electronics power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
Continuous
At least one fault is present in this component.
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
Flashing
Firmware is being downloaded.
0.5 Hz
Flashing
Firmware download is complete. Wait for POWER ON
2 Hz
Flashing
Component recognition via LED is activated (p0154).
Note:
Both options depend on the LED status when component
recognition is activated via p0154 = 1.
Description, cause
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
Commissioning

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents