Terminal Module Tm15; Terminal Module Tm31 - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnosis
3.1 Diagnostics via LEDs
LED
Color
Orange
3.1.13

Terminal Module TM15

Table 3-15
Terminal Module TM15 - description of LEDs
LED
Color
READY
-
Green
Orange
Red
Green/
red
Green/
orange
or
Red/
orange
3.1.14

Terminal Module TM31

Table 3-16
Terminal Module TM31 - description of LEDs
LED
Color
READY
-
Green
Orange
122
State
Continuous
Electronics power supply for measuring system available.
Power supply >5 V.
Important:
Make sure that the connected encoder can be operated
with a 24 V power supply. If an encoder that is designed
for a 5 V supply is operated with a 24 V supply, this can
destroy the encoder electronics.
State
OFF
Electronics power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
Continuous
At least one fault is present in this component.
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
Flashing
Firmware is being downloaded.
0.5 Hz
Flashing
Firmware download is complete. Wait for POWER ON
2 Hz
Flashing
Component recognition via LED is activated (p0154).
Note:
Both options depend on the LED status when component
recognition is activated via p0154 = 1.
State
OFF
Electronics power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
Description, cause
Description, cause
Description, cause
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
Remedy
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
Remedy
Commissioning

Hide quick links:

Advertisement