Siemens SINAMICS S120 Commissioning Manual page 69

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

What to do?
2.
Configure drives
2.1
Control structure
2.2
Power unit
2.3
BICO power unit
Caution
If the infeed is controlled from another Control Unit, then the ready signal of the infeed must be connected to parameter
p0864 "infeed ready" of the drive through a digital input/output. If this is not taken into account, the infeed may be
damaged.
2.4
Drive setting
2.5
Motor
2.6
Motor data
2.7
Motor brake
2.8
Encoder
Commissioning
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
2.6 Initial commissioning using vector (booksize) as an example
The drives must be configured individually.
-> "Drives" -> Drive name -> Double-click "Configuration" ->
Click "Configure DDS"
You can activate the function modules.
You can select the control type.
The Wizard displays the data determined automatically from the
electronic type plate.
Infeed in operation
Control Unit: r0722.4 (digital input 4)
You can select the motor standard (IEC/NEMA) and power unit
application (duty cycles).
The name of the motor (e.g. tooling labeling) can be entered.
Enter motor data: Yes
Select motor type "1LAx".
You can enter the motor data on the type plate here.
If known, mechanical data for the motor and drive line can be
entered.
Equivalent circuit diagram data: No
Here, you can configure the brake and activate the "Extended
brake control" function module.
The encoder must be deselected in this example.
How to do it?
Commissioning
Remark
Caution
If a sinusoidal filter is
connected, it must be
activated here to prevent it
from being destroyed.
You can select a standard
motor from the list of
motors or you can enter the
motor data yourself. You
can then select the motor
type.
If you do not enter any
mechanical data, it is
estimated on the basis of
the data on the type plate.
The equivalent circuit
diagram data is also
estimated on the basis of
the data on the type plate
or determined by means of
automatic motor data
identification.
For further information: see
the Function Manual.
If you are using an encoder
that is not in the list, you
can also enter the data.
69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents