20.6.8 Setting the Access rights (Lock) parameter

The access to certain functions and areas can be restricted for the opera-
tor. If an access lock is set, it is shown in both the Manual and Automatic
modes. A key symbol appears on the display, on the right next to the pro-
gram number.
Various settings can be made for the access rights. The possibilities are
explained in more detail in the table.
Prog.Switch The last active program is fixed on the Operator level. It is not possible
Manual
Program
124
to change to a different program.
(Value range ON/OFF)
Selective restriction of areas in Manual mode
R/W – Read/Write
OFF – Area is hidden
R/O – Read Only
Restriction of access to the parameters
Parameters
(Value range R/W, OFF)
Restriction of access to the stitch length
Stitchlen.
(Value range R/W, OFF, R/O)
Restriction of access to the needle thread tension
Thr.Tens.
(Value range R/W, OFF, R/O)
Restriction of access to the foot pressure
Foot Press
(Value range R/W, OFF, R/O)
Restriction of access to the sewing foot stroke
Foot Stroke
(Value range R/W, OFF, R/O)
Selective restriction of access to the existing program and its parameters
R/W – Read/Write
OFF – Area is hidden
R/O – Read Only
It is not possible to create new programs; it is not
Programming
possible to edit existing programs
(Value range ON/OFF)
Restriction of access to the correction factor for
St.Len.Corr
the stitch length
(Value range R/W, OFF, R/O)
Restriction of access to the correction factor for
Tens.Corr
the needle thread tension
(Value range R/W, OFF, R/O)