Setting The Correction Of Effects Of High Speed (Speed Corr) Parameter; Setting The Light Barrier (Lightbarrier) Parameter - Dürkopp Adler 867-M PREMIUM Service Instructions Manual

Hide thumbs Also See for 867-M PREMIUM:
Table of Contents

Advertisement

Programming
20.5.16 Setting the Correction of effects of high speed (Speed Corr)
Various settings can be made for the correction of the effects of high
speed. The possibilities are explained in more detail in the table.
Menu item
Hysterese
(hysteresis)

20.5.17 Setting the light barrier (LightBarrier) parameter

Various settings can be made for the light barrier. The possibilities are ex-
plained in more detail in the table.
Menu item
ON/OFF
Speed
Fr.pedal.start Free
Sense
Automatic
Service Instructions 867-M PREMIUM - 03.0 - 05/2017
parameter
Setting options
Tolerance at which the correction of the effects of high speed based on
the second stitch length, the second needle thread tension and/or the
second sewing foot stroke switches back. This tolerance is designed to
ensure that there is not constant alternating between activation and
deactivation in the boundary range.
(Value range 0.0 – 2.0 [mm])
Setting options
Light barrier active/inactive.
The last stitches after the detection of the end of the material
(approx. 50 mm) can be sewn at a defined speed.
(Value range 0010 – 2000 [rpm])
Pedal start
ON
Pedal can be pressed and the machine sews as soon as the
material breaks the light barrier
OFF
Pedal is pressed but the machine does not start sewing; must be
started from neutral position
Dark
The signal is given when the light barrier is broken.
Bright
The signal is given when the light barrier is complete.
This setting is relevant only the material end detection is activated
on the Operator level.
ON
The pedal starts a program, which runs automatically.
OFF
The pedal starts a program; the operator determines the speed
through the end of the program.