Dürkopp Adler 867-M PREMIUM Service Instructions Manual page 111

Hide thumbs Also See for 867-M PREMIUM:
Table of Contents

Advertisement

Programming
Menu item
PWM Config
NSB
Service Instructions 867-M PREMIUM - 03.0 - 05/2017
Setting options
Pulse width modulation
Power supply to the magnet for the thread clamp.
t1 [ms]
Activation duration of thread clamp in time period t1.
(Value range 000 – 1000 [ms])
DtyC. t1 [%]
Duty cycle in time period t2
(Value range 000 – 1000 [%])
t2 [s]
Activation duration of thread clamp in time period t2.
(Value range 000 – 1000 [ms])
DtyC. t2 [%]
Duty cycle in time period t2
(Value range 000 – 1000 [%])
Neat Seam Beginning
(Value range ON/OFF)
Trim Delay
Delay after thread cutting, when NSB is activated.
(Value range 0000 – 1000 [ms])
Knife
Value for the first position of the knife after seam start.
(Value range 000 – 359)
Knife Clamp
Value for switching off the knife clamp.
(Value range 000 – 359)
Exhaust
Exhaust removal of the cut-off residual thread.
On° – Position for the start of exhaust removal (value range 000 – 359)
Off – duration of the exhaust removal (value range 00000 – 99999 [ms])