3. Loosen the screw (2) of the needle bar (1).
4. Move the height of the needle bar (1) such that the hook tip (4) is in
5. Tighten the screw (2) for the needle bar (1).
6. Finish the service routine.
Order
Then, check the following settings:
52
the middle of the lower third of the groove for the needle.
When doing so, take care not to twist the needle to the side.
The groove (3) must face toward the hook.
• Position of the needle guard ( p. 50)
Position of the hook and needle
Service Instructions 867-M PREMIUM - 03.0 - 05/2017