Setting The Timing For Lifting - Dürkopp Adler 867-M PREMIUM Service Instructions Manual

Hide thumbs Also See for 867-M PREMIUM:
Table of Contents

Advertisement

Setting the bobbin case lifter
Important
Ensure that the gap is not too big. The middle part of the hook must not
swing back and forth, hitting the slot in the throat plate (2).
7. Tighten the threaded pin (3).
8. Push the cover (4) upwards.
9. Tighten the screw (5).

11.2 Setting the timing for lifting

Fig. 42: Setting the timing for lifting
(1) - Plug
(2) - Hook housing
Proper setting
The bobbin case lifter starts to open exactly at the point when the hook tip
is located below the bobbin case lifter after the loop is taken up.
In 1-needle machines, this happens when the handwheel position is
approx. 100°.
In 2-needle machines, this happens when the handwheel position is
approx. 100° for the right-hand hook, and when the handwheel position is
approx. 300° for the left-hand hook.
For 100° or 300°, the threaded pin (4) is exactly in the middle of the open-
ing. (Insert hex key in the threaded pin for orientation).
To set the timing for lifting:
1. Tilt the machine head ( p. 16).
2. Remove the plug (1) on the bottom side of the hook housing (2).
3. Loosen the control cam threaded pin (4) through the opening.
4. Turn the handwheel until the hook tip is exactly below the bobbin case
5. Use the hex key to turn the control cam (3) so that the bobbin case
6. Tighten the threaded pin (4).
7. Insert the plug (1) into the opening.
8. Perform a sewing test.
Service Instructions 867-M PREMIUM - 03.0 - 05/2017
lifter.
lifter opens at the correct point in time.
(3) - Control cam
(4) - Threaded pin
55

Advertisement

Table of Contents
loading