Working basis
3.4.6
Fig. 10: Disassembling and assembling the throat plate
(1) - Screws
(2) - Throat plate
Disassembling the throat plate
To disassemble the throat plate:
1. Execute the service routine Feed Dog > Pos To Needle ( p. 14).
The software is used to define the necessary presettings on the
2. Open the throat plate slide ( p. 20)
3. Loosen the screws (1).
4. Remove the throat plate (2).
5. Finish the service routine.
Assembling the throat plate
To assemble the throat plate:
1. Execute the service routine Feed Dog > Pos To Needle ( p. 14).
The software is used to define the necessary presettings on the
2. Insert the throat plate (2).
Ensure that the nose (4) of the bobbin case (3) is in the cutout of the
3. Tighten the screws (1).
4. Close the throat plate slide ( p. 20).
5. Finish the service routine.
Service Instructions 867-M PREMIUM - 03.0 - 05/2017
Disassembling and assembling the throat plate
①
②
③
machine.
machine.
throat plate (2).
(3) - Bobbin case
(4) - Nose
④
21