Aligning the needle bar linkage

9
Order
First, check the following setting:
Proper setting
If the stitch length is 0, the needle pierces exactly in the center of the nee-
dle hole.

9.1 Aligning the needle bar linkage sideways

Fig. 31: Aligning the needle bar linkage sideways (1)
(1) - Threaded pins
(2) - Adjusting rings
To align the needle bar linkage sideways:
1. Execute the service routine Needle Hook > Needlebar ( p. 14).
 The software is used to define the necessary presettings on the
2. Remove the arm cover ( p. 17).
3. Remove the head cover ( p. 18).
4. Loosen the threaded pins (1) on the two adjusting rings (2) at the right-
Service Instructions 867-M PREMIUM - 03.0 - 05/2017
Aligning the needle bar linkage
WARNING
Risk of injury from moving parts!
Crushing possible.
Move the machine into the service routine before
aligning the needle bar linkage.
• A straight and undamaged needle has been inserted ( Operating
Instructions)
machine.
hand end of the shaft for the needle bar linkage.
(3) - Throat plate
(4) - Needle bar linkage