Setting The Output Configuration (Output Config) Parameter - Dürkopp Adler 867-M PREMIUM Service Instructions Manual

Hide thumbs Also See for 867-M PREMIUM:
Table of Contents

Advertisement

Programming
A mode can be allocated to every input (parameter T 53 00). The following
table lists the modes:
Menu item
Mode
Stored

20.6.4 Setting the Output configuration (Output Config) parameter

Configure and allocate the outputs here. The table shows the outputs and
their allocation. The pins on the circuit board are labeled and must be allo-
cated according to the table, depending on what was connected to the pin.
Machine output signal
ML (X22)
NK (X22)
RA (X16)
STL (X17)
STL(FA) (X18)
FL (X15) (X22)
FF3 OUT (X22)
Service Instructions 867-M PREMIUM - 03.0 - 05/2017
Setting options
0, 7, 9, 10, 13,
No function
14, 16, 17, 19,
22, 24
1
Threading position
2
Bartack active/inactive.
3
Manual bartack
4
Half stitch
5
Full stitch
6
Point position
8
Needle height
11
2nd Needle thread tension
12
Change of stitch length
15
Seam center guide/puller
18
Light barrier
20
Operation lock when contact is opened normally (NO)
21
Quick stroke height adjustment
23
Change to next seam section
25
2nd Position of edge guide
ON – stored
OFF – not stored
Output
X120B.9
X120B.10
X120B.12
X120B.22
X120B.23
X90.12
X90.15