Encoder phase angle (servo mode only)
With drive software version V01.08.00 onwards, the encoder phase angles in Pr 3.25 and Pr 21.20 are copied to the SMARTCARD when using
any of the SMARTCARD transfer methods.
With drive software version V01.05.00 to V01.07.01, the encoder phase angles in Pr 3.25 and Pr 21.20 are only copied to the SMARTCARD
WARNING
when using either Pr 0.30 set to Prog (2) or Pr xx.00 set to 3yyy.
This is useful when the SMARTCARD is used to back-up the parameter set of a drive but caution should be used if the SMARTCARD is used to
transfer parameter sets between drives.
Unless the encoder phase angle of the servo motor connected to the destination drive is known to be the same as the servo motor connected
to the source drive, an autotune should be performed or the encoder phase angle should be entered manually into Pr 3.25 (or Pr 21.20). If the
encoder phase angle is incorrect the drive may lose control of the motor resulting in an O.SPd or Enc10 trip when the drive is enabled.
With drive software version V01.04.00 and earlier, or when using software version V01.05.00 to V01.07.01 and Pr xx.00 set to 4yyy is used,
then the encoder phase angles in Pr 3.25 and Pr 21.20 are not copied to the SMARTCARD. Therefore, Pr 3.25 and Pr 21.20 in the destination
would not be changed during a transfer of this data block from the SMARTCARD.
11.20

Menu 22: Additional Menu 0 set-up

Parameter
22.01 Parameter 0.31 set-up
22.02 Parameter 0.32 set-up
22.03 Parameter 0.33 set-up
22.04 Parameter 0.34 set-up
22.05 Parameter 0.35 set-up
22.06 Parameter 0.36 set-up
22.07 Parameter 0.37 set-up
22.10 Parameter 0.40 set-up
22.11 Parameter 0.41 set-up
22.18 Parameter 0.48 set-up
22.20 Parameter 0.50 set-up
22.21 Parameter 0.51 set-up
22.22 Parameter 0.52 set-up
22.23 Parameter 0.53 set-up
22.24 Parameter 0.54 set-up
22.25 Parameter 0.55 set-up
22.26 Parameter 0.56 set-up
22.27 Parameter 0.57 set-up
22.28 Parameter 0.58 set-up
22.29 Parameter 0.59 set-up
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
Range( )
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
OL
Pr 6.09
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
Default( )
VT
SV
Pr 11.33
RW Uni
Pr 11.32
RW Uni
Pr 5.16
Pr 0.00
RW Uni
Pr 11.30
RW Uni
Pr 11.24
RW Uni
Pr 11.25
RW Uni
Pr 11.23
RW Uni
Pr 5.12
RW Uni
Pr 5.18
RW Uni
Pr 11.31
RW Uni
Pr 11.29
RW Uni
Pr 10.37
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Txt
Text string
US
User save
PS
UL Listing
Information
Type
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
Power down save