Table 12-25 Size 0 (200V) Emission Compliance (Single And Three Phase Drives); Table 12-26 Size 0 (400V) Emission Compliance; Table 12-27 Size 1 Emission Compliance; Table 12-28 Size 2 Emission Compliance - Emerson unidrive sp User Manual

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Table 12-25 Size 0 (200V) emission compliance (single and three
phase drives)
Switching frequency (kHz)
Motor cable
length (m)
3
4
Using internal filter:
0 to 7
7 to 9
9 to 11
E2U
>11
Using external filter:
0 to 20
R
20 to 100

Table 12-26 Size 0 (400V) emission compliance

Switching frequency (kHz)
Motor cable
length (m)
3
4
Using internal filter:
0 to 6
E2U
6 to 12
E2U
12 to 14
E2U
>14
Using external filter:
0 to 20
R
20 to 70
70 to 100
I

Table 12-27 Size 1 emission compliance

Switching frequency (kHz)
Motor cable
length (m)
3
4
Using internal filter:
0 to 4
E2U
>4
Using internal filter and external ferrite ring:
0 to 10
E2U
> 10
Using external filter:
0 to 25
R
25 to 75
75 to 100
I

Table 12-28 Size 2 emission compliance

Switching frequency (kHz)
Motor cable
length (m)
3
4
Using internal filter:
Any
Using internal filter and external ferrite ring:
0 to 4
E2U
4 to 10
E2U
> 10
Using external filter:
0 to 25
R
25 to 75
75 to 100
I
278
Electrical
Getting
Basic
installation
Started
parameters
6
8
12
E2U
E2U
E2R
E2R
E2R
I
I
6
8
12
E2R
E2R
E2R
E2R
I
I
Do not use
6
8
12
E2R
E2R
E2R
E2R
I
I
Do not use
Do not use
6
8
12
E2R
E2R
E2R
E2R
I
I
Do not use
Do not use
www.controltechniques.com
Running
SMARTCARD
Optimization
the motor
operation

Table 12-29 Size 3 emission compliance

Motor cable
length (m)
16
Using internal filter:
Any
TBC
Using external filter:
TBC
0 to 20
TBC
20 to 50
TBC
50 to 75
75 to 100
Table 12-30 Size 4 (200V & 400V) emission compliance
Motor cable length
(m)
Using internal filter:
16
Any
Using external filter:
TBC
0 to 25
TBC
25 to 50
TBC
50 to 75
TBC
75 to 100

Table 12-31 Size 4 (690V) emission compliance

Motor cable length
(m)
Using internal filter:
Any
Using external filter:
16
0 to 25
25 to 50
50 to 75
75 to 100

Table 12-32 Size 5 (400V) emission compliance

Motor cable length
(m)
Using internal filter:
100
Using external filter:
0 to 100

Table 12-33 Size 5 (690V) emission compliance

Motor cable length
16
(m)
Using internal filter:
100
Using external filter:
0 to 25
0 to 100
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
Switching frequency (kHz)
3
4
6
E2R
R
I
I
I
I
Do not use
Switching frequency (kHz)
3
4
E2R
I
I
I
E2U
I
E2U
Switching frequency (kHz)
3
4
E2R
I
I
I
I
Switching frequency (kHz)
3
4
E2U
I
Switching frequency (kHz)
3
4
E2R
I
I
Unidrive SP User Guide
Issue Number: 13
UL Listing
Information
8
12
Do not
use
6
8
6
8
E2U
E2U
E2U
6
8
6
8
Do not use

Hide quick links:

Advertisement

Table of Contents
loading