Safety
Product
Mechanical
Information
Information
Installation
SM-I/O Timer & SM-I/O Lite parameters
Parameter
x.01
Solutions Module ID
x.02
Solutions Module software version
x.03
Current loop loss indicator
x.04
T5 digital input 1 state
x.05
T6 digital input 2 state
x.06
T7 digital input 3 state
x.07
Relay 1 state
x.14
T5 digital input 1 invert
x.15
T6 digital input 2 invert
x.16
T7 digital input 3 invert
x.17
Relay 1 invert
x.19
Real time clock daylight saving mode
x.20
Digital I/O read word
x.24
T5 digital input 1 destination
x.25
T6 digital input 2 destination
x.26
T7 digital input 3 destination
x.27
Relay 1 source
x.30
Real time clock update mode
x.34
Real time clock time: minutes.seconds
x.35
Real time clock time: days.hours
x.36
Real time clock time: months.days
x.37
Real time clock time: years
x.38
Analog input 1 mode
x.39
Analog output mode
x.40
Analog input 1
x.41
Analog input 1 scaling
x.42
Analog input 1 invert
x.43
Analog input 1 destination
x.48
Analog output 1 source
x.49
Analog output 1 scaling
x.50
Solutions Module error status*
x.51
Solutions Module software sub-version
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
*See trip SLX.Er, Automation (I/O Expansion) module category on page 294.
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
Range( )
0 to 599
0.00 to 99.99
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0 to 255
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
0 to 2
0.00 to 59.59
1.00 to 7.23
0.00 to 12.31
2000 to 2099
0-20 (0), 20-0 (1), 4-20.tr (2),
20-4.tr (3), 4-20 (4), 20-4 (5),
VOLt(6)
0-20 (0), 20-0 (1), 4-20 (2), 20-4 (3),
VOLt (4)
±100.0%
0 to 4.000
OFF (0) or On (1)
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
0.000 to 4.000
0 to 255
0 to 99
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
Default( )
SM-I/O Timer: 203
SM-I/O Lite: 207
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
0
0-20 (0)
0-20 (0)
1.000
OFF (0)
Pr 0.00
Pr 0.00
1.000
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
Type
RO Uni
PT US
RO Uni
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RO Bit
NC PT
RW Bit
RW Bit
RW Bit
RW Bit
RW Bit
RO Uni
NC PT
RW Uni DE
PT US
RW Uni DE
PT US
RW Uni DE
PT US
RW Uni
PT US
RW Uni
NC
RW Uni
NC PT
RW Uni
NC PT
RW Uni
NC PT
RW Uni
NC PT
RW Txt
RW Txt
RO
Bi
NC PT
RW Uni
RW Bit
RW Uni DE
PT US
RW Uni
PT US
RW Uni
RO Uni
NC PT
RO Uni
NC PT
Txt
Text string
US
User save
PS
UL Listing
Information
SM-I/O
Lite
Timer
US
US
US
US
US
US
US
US
US
US
Power down save