Menu 10: Status and trips

Parameter
10.01 Drive OK
10.02 Drive active
10.03 Zero speed
Running at or below minimum
10.04
speed
10.05 Below set speed
10.06 At speed
10.07 Above set speed
10.08 Load reached
10.09 Drive output is at current limit
10.10 Regenerating
10.11 Braking IGBT active
10.12 Braking resistor alarm
10.13 Direction commanded
10.14 Direction running
10.15 Line power supply loss
10.16 Under voltage active
10.17 Overload alarm
10.18 Drive over temperature alarm
10.19 Drive warning
10.20 Trip 0
10.21 Trip 1
10.22 Trip 2
10.23 Trip 3
10.24 Trip 4
10.25 Trip 5
10.26 Trip 6
10.27 Trip 7
10.28 Trip 8
10.29 Trip 9
10.30 Full power braking time
10.31 Full power braking period
10.32 External trip
10.33 Drive reset
10.34 No. of auto-reset attempts
10.35 Auto-reset delay
Hold drive OK until last
10.36
attempt
10.37 Action on trip detection
10.38 User trip
Braking energy overload
10.39
accumulator
10.40 Status word
10.41 Trip 0 time: years.days
Module number for trip 0, or, Trip 0
10.42
time: hours.minutes
10.43 Module number for trip 1, or, Trip 1 time
10.44 Module number for trip 2, or, Trip 2 time
10.45 Module number for trip 3, or, Trip 3 time
10.46 Module number for trip 4, or, Trip 4 time
10.47 Module number for trip 5, or, Trip 5 time
10.48 Module number for trip 6, or, Trip 6 time
10.49 Module number for trip 7, or, Trip 7 time
10.50 Module number for trip 8, or, Trip 8 time
10.51 Module number for trip 9, or, Trip 9 time
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
*The value given for the range is that obtained via serial communication.
For the text string displayed on the drive, see Chapter 13 Diagnostics on
page 283.
200
Electrical
Getting
Basic
installation
Started
parameters
Range( )
OL
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1) [0 = FWD, 1 = REV]
OFF (0) or On (1) [0 = FWD, 1 = REV]
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0 to 232*
0 to 232*
0 to 232*
0 to 232*
0 to 232*
0 to 232*
0 to 232*
0 to 232*
0 to 232*
0 to 232*
0.00 to 400.00 s
0.0 to 1500.0 s
OFF (0) or On (1)
OFF (0) or On (1)
0 to 5
0.0 to 25.0 s
OFF (0) or On (1)
0 to 15
0 to 255
0.0 to 100.0 %
0 to 32,767
0.000 to 9.365 years.days
00.00 to 23.59 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
0 to 600.00 hours.minutes
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running
SMARTCARD
Optimization
the motor
operation
CL
OL
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected

Table 11-6 Defaults for Pr 10.30 and Pr 10.31

Drive rating
200V, size 0
400V, size 0
200V, size 1 & 2
400V, size 1 & 2
All other ratings and frame sizes
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
Default( )
VT
SV
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Txt
RO Txt
RO Txt
RO Txt
RO Txt
RO Txt
RO Txt
RO Txt
RO Txt
RO Txt
See Table 11-6
RW Uni
See Table 11-6
RW Uni
OFF (0)
RW Bit
OFF (0)
RW Bit
0
RW Uni
1.0
RW Uni
OFF (0)
RW Bit
0
RW Uni
0
RW Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
RO Uni
Txt
Text string
US
User save
PS
Pr 10.30
0.06
0.01
0.09
0.02
Unidrive SP User Guide
UL Listing
Information
Type
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
US
US
NC
NC
US
US
US
US
NC
NC PT
NC PT
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
NC PT PS
Power down save
Pr 10.31
2.6
1.7
3.3
3.3
0.00
Issue Number: 13