Figure 11-44 Sm-I/O 24V Protected Analog Output Logic - Emerson unidrive sp User Manual

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Figure 11-44 SM-I/O 24V Protected analog output logic diagram
T10 Analog output 1
10
T12 Analog output 2
Input
terminals
Output
terminals
The parameters are all shown at their default settings
SM-I/O 24V Protected parameters
Parameter
x.01
Solutions Module ID
x.02
Solutions Module Main Software Version
x.03
T5 digital I/O 3 state
x.04
T6 digital I/O 4 state
x.05
T7 digital input 5 state
x.06
T8 digital input 6 state
x.07
T9 digital input 7 state
x.08
Relay 1 state
x.09
T3 digital I/O 1 state
x.10
T4 digital I/O 2 state
x.11
T3 digital I/O 1 invert
x.12
T4 digital I/O 2 invert
x.13
T5 digital I/O 3 invert
x.14
T6 digital I/O 4 invert
x.15
T7 digital input 5 invert
x.16
T8 digital input 6 invert
x.17
T9 digital input 7 invert
x.18
Relay 1 invert
x.20
Digital I/O read word
x.21
T3 digital I/O 1 source/destination
x.22
T4 digital I/O 2 source/destination
x.23
T5 digital I/O 3 source/destination
x.24
T6 digital I/O 4 source/destination
x.25
T7 digital input 5 destination
x.26
T8 digital input 6 destination
x.27
T9 digital input 7 destination
x.28
Relay 1 source
x.29
T6 digital I/O 4 output select
x.31
T3 digital I/O 1 output select
x.32
T4 digital I/O 2 output select
x.33
T5 digital I/O 3 output select
x.39
Analog output mode
x.40
Relay 2 state
x.42
Relay 2 invert
x.43
Relay 2 source
x.45
Analog output 2 scaling
x.47
Analog output 2 source
x.48
Analog output 1 source
x.49
Analog output 1 scaling
x.50
Solutions Module error status
x.51
Solutions Module software sub-version
244
Electrical
Getting
Basic
installation
Started
parameters
Key
Read-write (RW)
0.XX
parameter
Read-only (RO)
0.XX
parameter
Range( )
0.00 to 99.99
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0-20, 20-0, 4-20, 20-4
0.0 or 100.0 %
OFF (0) or On (1)
Pr 0.00 to Pr 21.51
0.000 to 4.000
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
0.000 to 4.000
www.controltechniques.com
Running
SMARTCARD
Optimization
the motor
operation
Default( )
0 to 599
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
0 to 255
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
OFF (0)
OFF (0)
OFF (0)
OFF (0)
Pr 0.00
Pr 0.00
Pr 0.00
0 to 255
0 to 99
Onboard
Advanced
Technical
PLC
parameters
Data
205
RO
Uni
RO
Uni
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RO
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
On (1)
RW
Bit
RW
Bit
RW
Bit
RW
Bit
0-20
RW
Uni
RO
Bit
RW
Bit
RW
Uni
1.000
RW
Uni
RW
Uni
RW
Uni
1.000
RW
Uni
RO
Uni
RO
Uni
Unidrive SP User Guide
UL Listing
Diagnostics
Information
Type
PT
US
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
US
US
US
US
US
US
US
US
NC
PT
DE
US
DE
US
DE
US
DE
US
DE
US
DE
US
DE
US
US
US
US
US
US
US
NC
PT
US
US
US
US
US
US
NC
PT
NC
PT