Advanced Menus; Table 5-1 Advanced Menu Descriptions; Table 5-2 Menu 40 Parameter Descriptions; Table 5-3 Menu 41 Parameter Descriptions - Emerson unidrive sp User Manual

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
5.5

Advanced menus

The advanced menus consist of groups or parameters appropriate to a
specific function or feature of the drive. Menus 0 to 22 can be viewed on
all keypads. Menus 40 and 41 are specific to the SM-Keypad Plus
(LCD). Menus 70 to 91 can be viewed with an SM-Keypad Plus (LCD)
only when an SM-Applications is installed.

Table 5-1 Advanced menu descriptions

Menu
Description
Commonly used basic set up parameters for quick
0
/ easy programming
1
Frequency / speed reference
2
Ramps
Slave frequency, speed feedback and speed
3
control
4
Torque and current control
5
Motor control
6
Sequencer and clock
7
Analog I/O
8
Digital I/O
Programmable logic, motorized pot and binary
9
sum
10
Status and trips
11
General drive set-up
12
Threshold detectors and variable selectors
13
Position control
14
User PID controller
15,
Solutions Module set-up
16, 17
18
Application menu 1
19
Application menu 2
20
Application menu 3
21
Second motor parameters
22
Additional Menu 0 set-up
40
Keypad configuration menu
41
User filter menu
70
PLC registers
71
PLC registers
72
PLC registers
73
PLC registers
74
PLC registers
75
PLC registers
85
Timer function parameters
86
Digital I/O parameters
88
Status parameters
90
General parameters
91
Fast access parameters
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
LED LCD
X
X
X
X
X
X
X
X
X
X
X
X
X
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
5.5.1
SM-Keypad Plus set-up menus

Table 5-2 Menu 40 parameter descriptions

Parameter
40.00 Parameter 0
40.01 Language selection
40.02 Software version
40.03 Save to flash
40.04 LCD contrast
Drive and attribute database
40.05
upload was bypassed
40.06 Browsing favourites control
40.07 Keypad security code
Communication channel
40.08
selection
40.09 Hardware key code
40.10 Drive node ID (Address)
40.11
Flash ROM memory size
40.19 String database version number
40.20 Screen saver strings and enable
40.21 Screen saver interval
40.22 Turbo browse time interval

Table 5-3 Menu 41 parameter descriptions

Parameter
41.00 Parameter 0
41.01
to
Browsing filter source F01 to F50
41.50
41.51 Browsing favourites control
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
English (0), Custom (1),
French (2), German (3),
Spanish (4), Italian (5)
Idle (0), Save (1),
Restore (2), Default (3)
Updated (0), Bypass (1)
Normal (0), Filter (1)
Disable (0), Slot1 (1), Slot2
(2), Slot3 (3), Slave (4),
4Mbit (0), 8Mbit (1)
0 to 999999
None (0), Default (1),
Pr 0.00 to Pr 391.51
Normal (0), Filter (1)
UL Listing
Information
Range( )
0 to 32767
999999
0 to 31
0 to 999
Direct (5)
0 to 999
0 to 255
User (2)
0 to 600
0 to 200ms
Range( )
0 to 32767