Selecting The Language On The Tft And Oled Display; Operating Displays; Additional Display Messages - Emerson PACMotion VFD Series User Manual

Ac variable speed drive
Hide thumbs Also See for PACMotion VFD Series:
Table of Contents

Advertisement

Selecting the Language on the TFT and OLED Display

VFD
01
Select Language
STOP
15 kW 400 V 3 Ph
Hold down the
Use the Up and
Start and Up keys
Down arrows to
for >1s.
select a language.

Operating Displays

Inhibit /
Drive Stopped
STO Active
TFT and OLED Display :
VFD
01
VFD
INHIBIT
15 kW 400 V 3 Ph 15 kW 400 V 3 Ph 15 .3 A
Drive Inhibited.
Drive Stopped /
The STO
Disabled.
connections are
not made. Refer
to section
Figure 28:
Recommended
"STO" Wiring on
page 38.

Additional Display Messages

Auto Tuning in
External 24V DC
Progress
Supply
TFT and OLED Display :
VFD
Ext 24 V
Auto-tuning
External 24V mode 15 .3 A
Auto tune in
The drive control
progress. See
board is powered
parameter P4-02
only from an
information in
external 24 Volt
section Parameter
source, with no
Group 4 – High
mains power
Performance
applied.
Motor Control on
page 63.
GFK-3111A
Select Language
Español
Español
Deutsch
Deutsch
English
English
Press the Navigate
button to select.
Drive Running
Output Freq
Display
01
Output Frequency 01
STOP
23.7 Hz
Drive is enabled /
running, display
shows the output
frequency
(Hz). Press the
Navigate key to
select alternative
displays.
Overload
01
VFD
23.7 Hz
OL
Indicates an
Overload
condition. Output
current exceeds
the motor rated
current entered in
Parameter P1-08.
PACMotion VFD AC Variable Speed Drive User Guide
Drive Running
Output Current
Display
Motor Current 01
15.3 A
6 .9 kW 6 .9 kW
23 .7 Hz 23 .7 Hz
Press the Navigate
key for < 1 second.
The display will
show the motor
current (Amps).
Switching Freq
Display
01
VFD
01
23.7 Hz
SF
6 .9 HP 15 .3 A
6 .9 HP
Switching
frequency is
reduced, due to
high heatsink
temperature.
Drive Running
Drive Running
Motor Power
Motor Speed
Display
Display
Motor Power 01
Motor Speed
6.9 kW
718 rpm
15 .3 A 23 .7 Hz
Press the Navigate
If P1-10 > 0,
key for < 1 second.
pressing the
Navigate key for
The display will
< 1 second will
show the motor
display the motor
power (HP).
speed (RPM).
Mains Loss
Maintenance
Time Elapsed
VFD
01
VFD
23.7 Hz
ML
15 .3 A
6 .9 kW
15 .3 A
The incoming
The user
mains power
programmable
supply has been
maintenance
disconnected or is
reminder time has
missing.
elapsed.
01
15 .3 A
01
23.7 Hz
6 .9 kW
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents