Emerson unidrive sp User Manual page 225

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Positional information
Revolution
counter
x.04
Lock position
feedback
x.49
Revolution
counter
Position
x.29
x.30
Non marker reset
positional information
SM-Resolver parameters
Parameter
x.01
Solutions Module ID
x.03
Speed
x.04
Revolution counter
x.05
Position
x.10
Equivalent lines per revolution
x.13
Resolver excitation
x.15
Resolver poles
x.17
Error detection level
x.19
Feedback filter
x.24
Encoder simulation source
x.25
Encoder simulation ratio numerator
x.29
Non-marker reset revolution counter
x.30
Non-marker reset position
x.35
Freeze revolution counter
x.36
Freeze position
x.39
Freeze flag
x.45
Position feedback initialized
x.49
Lock position feedback
x.50
Solutions Module error status*
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
*See trip SLX.Er, Feedback module category on page 292.
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
Position
x.05
Resolver
selected as
drive feedback
(Pr
3.26
)
Position
Resolver
x.05
source
Encoder
source
Range( )
0 to 599
±40,000.0 rpm
0 to 65,535 revolutions
16
0 to 65,535 1/2
ths of a revolution
0 to 50,000
3:1 (0), 2:1 (1 or 2)
2 pole (0), 4 pole (1), 6 pole (2),
8 pole (3 to 12)
Bit 0 (LSB) = Wire break detect
Bit 1 = Not used
Bit 2 (MSB) = Not used
0 (0), 1 (1), 2 (2), 4 (3), 8 (4), 16 (5) ms
Pr 0.00 to Pr 21.51
0.0000 to 3.0000
0 to 65,535 revolutions
16
0 to 65,535 1/2
ths of a revolution
0 to 65,535 revolutions
16
0 to 65,535 1/2
ths of a revolution
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0 to 255
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
Input
terminals
Output
terminals
The parameters are all shown at their default settings
Speed
feedback
Feedback
filter
x.19
x.03
Encoder
simulation
source
x.24
Ratio
numerator
x.25
3.29
x.xx
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
PLC
parameters
Data
Key
Read-write (RW)
0.XX
parameter
Read-only (RO)
0.XX
parameter
Simulated encoder
Term
output connections
1
A
2
A\
3
0V
4
B
5
B\
6
0V
7
Z
8
Z\
Default( )
101
RO Uni
RO
RO Uni FI NC PT
RO Uni FI NC PT
4096
RW Uni
3:1 (0)
RW Uni
2 pole (0)
RW Uni
1
RW Uni
0
RW Txt
Pr 0.00
RW Uni
0.25
RW Uni
RO Uni
RO Uni
RO Uni
RO Uni
OFF (0)
RW Bit
RO Bit
OFF (0)
RW Bit
RO Uni
Txt
Text string
US
User save
UL Listing
Diagnostics
Information
Type
PT US
Bi
FI NC PT
US
US
US
US
US
PT US
US
NC PT
NC PT
NC PT
NC PT
NC
NC PT
NC
NC PT
PS
Power down save
225

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents