Emerson unidrive sp User Manual page 241

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
SM-I/O PELV parameters
Parameter
x.01
Solutions Module ID
x.02
Solutions Module software version
x.03
T5 digital I/O 3 state
x.04
T6 digital I/O 4 state
x.05
T7 digital input 5 state
x.07
Relay 1 state
x.08
Relay 2 state
x.09
T3 digital I/O 1 state
x.10
T4 digital I/O 2 state
x.11
T3 digital I/O 1 invert
x.12
T4 digital I/O 2 invert
x.13
T5 digital I/O 3 invert
x.14
T6 digital I/O 4 invert
x.15
T7 digital input 5 invert
Disable PELV User power
x.16
supply absent trip
x.17
Relay 1 invert
x.18
Relay 2 invert
x.19
Freeze flag
x.20
Digital I/O read word
x.21
T3 digital I/O 1 source/destination
x.22
T4 digital I/O 2 source/destination
x.23
T5 digital I/O 3 source/destination
x.24
T6 digital I/O 4 source/destination
x.25
T7 digital input 5 destination
x.27
Relay 1 source
x.28
Relay 2 source
x.29
T6 digital I/O 4 output select
x.31
T3 digital I/O 1 output select
x.32
T4 digital I/O 2 output select
x.33
T5 digital I/O 3 output select
x.38
Analog input 1 mode
x.39
Analog output mode
x.40
Analog input 1 level
x.41
Analog input 1 scaling
x.42
Analog input 1 invert
x.43
Analog input 1 destination
x.45
Analog output 2 scaling
x.47
Analog output 2 source
x.48
Analog output 1 source
x.49
Analog output 1 scaling
x.50
Solutions Module error status*
x.51
Solutions Module software sub-version
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
*See trip SLX.Er, Automation (I/O Expansion) module category on page 294.
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
Range( )
0 to 599
0.00 to 99.99
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0 to 255
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0-20 (0), 20-0 (1), 4-20.tr (2), 20-4.tr (3),
4-20 (4), 20-4 (5)
0-20 (0), 20-0 (1), 4-20 (2), 20-4 (3)
0.0 to 100.0%
0.000 to 4.000
OFF (0) or On (1)
Pr 0.00 to Pr 21.51
0.000 to 4.000
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
0.000 to 4.000
0 to 255
0 to 99
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
Default( )
204
RO Uni
RO Uni
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
RO Uni
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni DE
Pr 0.00
RW Uni
Pr 0.00
RW Uni
On (1)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
0-20 (0)
RW Txt
0-20 (0)
RW Txt
RO
1.000
RW Uni
OFF (0)
RW Bit
Pr 0.00
RW Uni DE
1.000
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
1.000
RW Uni
RO Uni
RO Uni
Txt
Text string
US
User save
PS
UL Listing
Information
Type
PT US
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
US
US
US
US
US
US
US
US
US
NC PT
PT US
PT US
PT US
PT US
PT US
PT US
PT US
US
US
US
US
US
US
Bi
NC PT
US
US
PT US
US
PT US
PT US
US
NC PT
NC PT
Power down save
241

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents