Safety
Product
Mechanical
Information
Information
Installation
14

UL Listing Information

Size 0 to 6 drives have been assessed to meet both UL and cUL
requirements.
The Control Techniques UL file number is E171230. Confirmation of UL
listing can be found on the UL website: www.ul.com.
14.1

Common UL information

Conformity
The drive conforms to UL listing requirements only when the following
are observed:
The drive is installed in a type 1 enclosure, or better, as defined by
UL50
The surrounding air temperature does not exceed 40°C (104°F)
when the drive is operating
The terminal tightening torques specified in section 3.12.2 Terminal
sizes and torque settings on page 65
If the drive control stage is supplied by an external power supply
(+24V), the external power supply must be a UL Class 2 power
supply
Motor overload protection
The drive provides motor overload protection. The default overload
protection level is no higher than 150% of full-load current (FLC) of the
drive in open loop mode and no higher than 175% of full-load current
(FLC) of the drive in closed loop vector or servo modes. It is necessary
for the motor rated current to be entered into Pr 0.46 (or Pr 5.07) for the
protection to operate correctly. The protection level may be adjusted
below 150% if required. Refer to section 8.3 Current limits on page 147
for more information. The drive also provides motor thermal protection.
Refer to section 8.4 Motor thermal protection on page 147.
Overspeed Protection
The drive provides overspeed protection. However, it does not provide
the level of protection afforded by an independent high integrity
overspeed protection device.
14.2

Power dependant UL information

Conformity
The drive conforms to UL listing requirements only when the following is
observed.
Fuses
Size 0 to 3
The correct UL-listed fast acting fuses (class CC or class J up to 30A
and class J above 30A), e.g. Bussman Limitron KTK-R series,
Ferraz Shawmut ATMR series or equivalent, are used in the AC
supply. The drive does not comply with UL if MCBs are used in place
of fuses.
For further details on fusing, refer to in Table 4-3 and Table 4-4 on page 74.
Size 4 to 6
The UL-listed Ferraz HSJ (High speed J class) fuses are used in the
AC supply. The drive does not comply with UL if any other fuses or
MCBs are used in place of those stated.
For further details on fusing, refer to Table 4-5 on page 75.
Field wiring
Size 0 to 4
Class 1 60/75°C (140/167°F) copper wire only is used in the
installation
Size 5 and 6
Class 1 75°C (167°F) copper wire only is used in the installation
Field wiring connectors
Sizes 4 to 6
UL listed wire connectors are used for terminating power circuit field
wiring, e.g. Ilsco TA series
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
14.3

AC supply specification

The drive is suitable for use in a circuit capable of delivering not more
than 100,000rms symmetrical Amperes at 264Vac rms maximum (200V
drives), 528Vac rms maximum (400V drives) or 600Vac rms maximum
(575V and 690V drives).
14.4

Maximum continuous output current

The drive models are listed as having the maximum continuous output
currents (FLC) shown in Table 14-1, Table 14-2, Table 14-3 and Table
14-4 (see Chapter 12 Technical Data on page 265 for details).

Table 14-1 Maximum continuous output current (200V drives)

Model
0201
0202
0203
0204
0205
1201
1202
1203
1204

Table 14-2 Maximum continuous output current (400V drives)

Model
0401
0402
0403
0404
0405
1401
1402
1403
1404
1405
1406

Table 14-3 Maximum continuous output current (575V drives)

Model
3501
3502
3503
3504

Table 14-4 Maximum continuous output current (690V drives)

Model
4601
4602
4603
4604
4605
4606
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
FLC (A)
Model
2.2
2201
3.1
2202
4.0
2203
5.7
3201
7.5
3202
5.2
4201
6.8
4202
9.6
4203
11
5201
5202
FLC (A)
Model
1.3
2401
1.7
2402
2.1
2403
3.0
2404
4.2
3401
2.8
3402
3.8
3403
5.0
4401
6.9
4402
8.8
4403
11
5401
5402
6401
6402
FLC (A)
Model
5.4
3505
6.1
3506
8.3
3507
11
FLC (A)
Model
22
5601
27
5602
36
6601
43
6602
52
62
UL Listing
Information
FLC (A)
15.5
22
28
42
54
68
80
104
130
154
FLC (A)
15.3
21
29
29
35
43
56
68
83
104
138
168
205
236
FLC (A)
16
22
27
FLC (A)
84
99
125
144