Safety
Product
Mechanical
Information
Information
Installation
3.13

Routine maintenance

The drive should be installed in a cool, clean, well ventilated location. Contact of moisture and dust with the drive should be prevented.
Regular checks of the following should be carried out to ensure drive / installation reliability are maximized:
Environment
Ambient temperature
Ensure the enclosure temperature remains at or below maximum specified
Ensure the drive remains dust free – check that the heatsink and drive fan are not gathering dust. The lifetime of the
Dust
fan is reduced in dusty environments.
Moisture
Ensure the drive enclosure shows no signs of condensation
Enclosure
Enclosure door filters
Ensure filters are not blocked and that air is free to flow
Electrical
Screw connections
Ensure all screw terminals remain tight
Crimp terminals
Ensure all crimp terminals remains tight – check for any discoloration which could indicate overheating
Cables
Check all cables for signs of damage