9.5

SMARTCARD trips

After an attempt to read, write or erase data to or from a SMARTCARD a trip may occur if there has been a problem with the command. The following
trips indicate various problems as detailed in Table 9-4.

Table 9-4 Trip conditions

Trip
C.Acc
SMARTCARD trip: SMARTCARD Read / Write fail
Check SMARTCARD is installed / located correctly
185
Ensure SMARTCARD is not writing data to data location 500 to 999
Replace SMARTCARD
SMARTCARD trip: The menu 0 parameter modification cannot be saved to the SMARTCARD because the necessary file has
C.boot
not been created on the SMARTCARD
A write to a menu 0 parameter has been initiated via the keypad with Pr 11.42 set to auto(3) or boot(4), but the necessary file on the
SMARTCARD has not been created
177
Ensure that Pr 11.42 is correctly set and reset the drive to create the necessary file on the SMARTCARD
Re-attempt the parameter write to the menu 0 parameter
C.bUSY
SMARTCARD trip: SMARTCARD can not perform the required function as it is being accessed by a Solutions Module
178
Wait for the Solutions Module to finish accessing the SMARTCARD and then re-attempt the required function
C.Chg
SMARTCARD trip: Data location already contains data
Erase data in data location
179
Write data to an alternative data location
C.Cpr
SMARTCARD trip: The values stored in the drive and the values in the data block on the SMARTCARD are different
188
Press the red
C.dat
SMARTCARD trip: Data location specified does not contain any data
183
Ensure data block number is correct
C.Err
SMARTCARD trip: SMARTCARD data is corrupted
Ensure the card is located correctly
182
Erase data and retry
Replace SMARTCARD
C.Full
SMARTCARD trip: SMARTCARD full
184
Delete a data block or use a different SMARTCARD
C.Optn
SMARTCARD trip: Solutions Modules installed are different between source drive and destination drive
Ensure correct Solutions Modules are installed
Ensure Solutions Modules are in the same Solutions Module slot
180
Press the red
C.Prod
SMARTCARD trip: The data blocks on the SMARTCARD are not compatible with this product
Erase all data on the SMARTCARD by setting Pr xx.00 to 9999 and pressing the red
175
Replace SMARTCARD
C.rdo
SMARTCARD trip: SMARTCARD has the Read only bit set
Enter 9777 in Pr xx.00 to allow SMARTCARD Read / Write access
181
Ensure the drive is not writing to data locations 500 to 999 on the card
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
reset button
reset button
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
Diagnosis
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
reset button
UL Listing
Information
155

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents