Emerson unidrive sp User Manual page 293

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Trip
SLX.Er
Solutions Module slot X trip: Solutions Module in slot X has detected a fault
Automation (Applications) module category
Check value in Pr 15/16/17.50. The following table lists the possible error codes for the SM-Applications and SM-Applications Lite.
See the Diagnostics section in the relevant Solutions Module User Guide for more information.
Error Code
39
40
41
42
43
44
45
46
48
49
50
51
52
53
54
55
56
57
58
59
60
202,207,212
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
Trip Description
User program stack overflow
Unknown error - please contact supplier
Parameter does not exist
Attempt to write to a read-only parameter
Attempt to read from a write-only parameter
Parameter value out of range
Invalid synchronisation modes
Unused
RS485 not in user mode
Invalid RS485 configuration
Maths error - divide by zero or overflow
Array index out of range
Control word user trip
DPL program incompatible with target
DPL task overrun
Unused
Invalid timer unit configuration
Function block does not exist
Flash PLC Storage corrupt
Drive rejected application module as Sync master
CTNet hardware failure. Please contact your supplier
CTNet invalid configuration
CTNet invalid baud-rate
CTNet invalid node ID
Digital Output overload
Invalid function block parameter(s)
User heap too large
RAM file does not exist or a non-RAM file id has been specified
The RAM file specified is not associated to an array
Failed to update drive parameter database cache in Flash memory
User program downloaded while drive enabled
Failed to change drive mode
Invalid CTNet buffer operation
Fast parameter initialisation failure
Over-temperature
Hardware unavailable
Module type cannot be resolved. Module is not recognised.
Inter-option module comms error with module in slot 1
Inter-option module comms error with module in slot 2
Inter-option module comms error with module in slot 3
Inter-option module comms error with module unknown slot
APC internal error
Communications to drive faulty
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
Diagnosis
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
UL Listing
Information
293

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents