Mounting Methods; Figure 3-15 Mounting The Size 0 Using A Din Rail - Emerson unidrive sp User Manual

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
3.5

Mounting methods

Size 0 can be mounted using a DIN rail, either fixed at the top or the bottom of the drive (as illustrated in Figure 3-15). Two screws are required to fix
the drive to the back-plate at the opposite end to the DIN rail.

Figure 3-15 Mounting the size 0 using a DIN rail

47mm (1.85in)
312.7mm
(12.31in)
Unidrive SP size 1 to 6 units can be either surface or through-panel mounted using the appropriate brackets. Size 0 can only be surface mounted.
The following drawings show the dimensions of the drive and mounting holes for each method to allow a back plate to be prepared.
If the drive has been used at high load levels for a period of time, the heatsink can reach temperatures in excess of 70°C (158°F). Human
contact with the heatsink should be prevented.
WARNING
Many of the drives in this product range weigh in excess of 15kg (33lb). Use appropriate safeguards when lifting these models.
A full list of drive weights can be found in section 12.1.19 Weights on page 273.
WARNING
Unidrive SP User Guide
Issue Number: 13
Electrical
Getting
Basic
installation
Started
parameters
the motor
www.controltechniques.com
Running
SMARTCARD
Optimization
operation
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
UL Listing
Information
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents