Emerson unidrive sp User Manual page 188

Universal variable speed ac drive for induction and servo motors model sizes 0 to 6
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Parameter
5.01
Output frequency
5.02
Output voltage
5.03
Output power
5.04
Motor rpm
5.05
D.C bus voltage
5.06
Rated frequency
5.07
Motor rated current
5.08
Rated load rpm / rated speed {0.45}
5.09
Rated voltage
5.10
Rated power factor
5.11
Number of motor poles
5.12
Autotune
Dynamic V/F / flux optimise
5.13
select
Voltage mode select
5.14
Action on enable
5.15
Low frequency voltage boost {0.08}
5.16
Rated rpm autotune
5.17
Stator resistance
Maximum switching
5.18
frequency
High stability space vector
5.19
modulation
5.20
Quasi-square enable
5.21
Field gain reduction
5.22
High speed servo mode enable
5.23
Voltage offset
σ
5.24
Transient inductance (
L
)
s
Stator inductance (L
)
5.25
s
High dynamic performance
5.26
enable
5.27
Enable slip compensation
Field weakening
5.28
compensation disable
5.29
Motor saturation breakpoint 1
5.30
Motor saturation breakpoint 2
5.31
Voltage controller gain
Motor torque per amp, K
5.32
t
Motor volts per 1,000 rpm, K
5.33
Disable auto switching
5.35
frequency change
5.36
Motor pole pitch
5.37
Actual switching frequency
5.38
Minimal movement phasing test angle
Minimal movement phasing
5.39
test pulse length
5.40
Spin start boost
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
188
Electrical
Getting
Basic
installation
Started
parameters
Range( )
OL
±SPEED_FREQ_
{0.11}
MAX Hz
0 to AC_voltage_max V
±Power_max kW
{0.10}
±180,000 rpm
0 to +DC_voltage_max V
{0.47}
0 to 3,000 Hz
{0.46}
0 to Rated_current_max A
0 to 180,000 rpm
{0.44}
0 to AC_VOLTAGE_SET_MAX V
{0.43}
OL & VT> 0.000 to 1.000
{0.42}
Auto to 120 Pole (0 to 60)
{0.40}
0 to 2
{0.09}
OFF (0) or On (1)
Ur_S (0), Ur (1),
{0.07}
Fd (2), Ur_Auto (3),
Ur_I (4), SrE (5)
0.0 to 25.0 % of motor rated voltage
{0.33}
Size 0: 0.000 to 65.000 x 10
Size 1 to 5: 0.000 to 65.000
Size 6: 0.000 to 65.000 x 10 m
{0.41}
3 (0), 4 (1), 6 (2), 8 (3), 12 (4), 16 (5) kHz
OFF (0) or On (1)
OFF (0) or On (1)
0.0 to 25.0 V
0.000 to 500.000 mH
OFF (0) or On (1)
0 to 30
e
OFF (0) or On (1)
0 to 655.35 mm
3 (0), 4 (1), 6 (2), 8 (3), 12 (4), 16 (5), 6 rEd (6),
12 rEd (7)
0.0 to 10.0
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running
SMARTCARD
Optimization
the motor
operation
CL
OL
±1,250.0 Hz
VT> 0 to 1,250.0 Hz
EUR> 50.0, USA> 60.0
Drive rated current [11.32]
EUR> 1,500
0.00 to 40,000.00 rpm
USA> 1,800
400V drive: EUR> 400, USA> 460
VT> 0 to 4
SV> 0 to 6
VT> OFF (0) or On (1)
Ur_I (4)
SV> nonE (0),
Ph EnL (1), Ph Init (2)
Size 0 to 3: 3.0
Size 4 & 5: 2.0
VT> 0 to 2
Ω
Ω
Ω
OFF (0)
OFF (0)
OFF (0) or On (1)
SV> OFF (0) or On (1)
0.0
VT> 0.00 to 5,000.00 mH
OFF (0) or On (1)
On (1)
VT> OFF (0) or On (1)
VT> 0 to 100% of rated
flux
VT> 0 to 100% of rated
flux
VT> 0.00 to 500.00
-1
N m A
SV> 0.00 to 500.00
-1
N m A
SV> 0 to 10,000 V
°
SV> 0.0 to 25.5
SV> 0 to 3
VT> 0.0 to 10.0
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
PLC
parameters
Data
Default( )
VT
SV
RO
RO Uni FI NC PT
RO
RO
RO Uni FI NC PT
RW Uni
RW Uni
EUR> 1,450.00
3,000.00
RW Uni
USA> 1,770.00
200V drive: 230
RW Uni
575V drive: 575
690V drive: 690
0.850
RW Uni
Auto (0)
6 POLE (3) RW Txt
0
RW Uni
OFF (0)
RW Bit
RW Txt
nonE(0)
RW Txt
RW Uni
Size 6: 1.0
0
RW Uni
0.0
RW Uni
3 (0)
6 (2)
RW Txt
RW Bit
RW Bit
OFF (0)
RW Bit
0
RW Bit
RW Uni
0.000
RW Uni
0.00
RW Uni
OFF (0)
RW Bit
RW Bit
OFF (0)
RW Bit
50
RW Uni
75
RW Uni
1
RW Uni
RO Uni
1.60
RW Uni
98
RW Uni
OFF (0)
RW Bit
0.00
RW Uni
RO Txt
5.0
RW Uni
0
RW Uni
1.0
RW Uni
Txt
Text string
US
User save
Unidrive SP User Guide
UL Listing
Diagnostics
Information
Type
Bi
FI NC PT
Bi
FI NC PT
Bi
FI NC PT
US
RA
US
US
RA
US
RA
US
US
NC
US
US
US
US
US
RA
US
RA
US
US
US
US
US
RA
US
RA
US
RA
US
US
US
US
US
US
US
US
US
US
US
US
NC PT
US
US
US
PS
Power down save
Issue Number: 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents