Plug; Configuration - Siemens SCALANCE XB-200 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.4 The "System" menu
● Restart with EtherNet/IP Defaults
Click this button to restore the default settings of the EtherNet/IP profile and to restart the
device. You must confirm the restart in a dialog box. The dialog box displays these
settings specially made for operation with the EtherNet/IP protocol.
5.4.18

PLUG

5.4.18.1

Configuration

NOTICE
Do not remove or insert a C-PLUG during operation
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is present at one second intervals. If it is
detected that the PLUG was removed, there is a restart.
Information about the configuration of the C-PLUG
This page provides detailed information about the configuration stored on the C-PLUG. It is
also possible to reset the PLUG to "factory defaults" or to load it with new contents.
Note
The action is only executed after you click the "Set Values" button.
The action cannot be undone.
If you decide against executing the function after making your selection, click the "Refresh"
button. As a result the data of this page is read from the device again and the selection is
canceled.
156
NOTICE
By resetting all the settings to the default settings of a profile, the IP address is also lost.
Following this, the device can only be accessed via the serial interface, using the
Primary Setup Tool or using DHCP.
With the appropriate attachment, a previously correctly configured device can cause
circulating frames after the reset and therefore the failure of the data traffic.
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04