Configuring with Web Based Management
5.7 The "Security" menu
On this page, you configure the login.
Description of the displayed boxes
The page contains the following boxes:
Note
To be able to use the login authentication "RADIUS", a RADIUS server must be stored and
configured for user authentication.
● Login Authentication
Specify how the login is made:
– Local
– RADIUS
– Local and RADIUS
– RADIUS and fallback Local
250
The authentication must be made locally on the device.
The authentication must be handled via a RADIUS server.
The authentication is possible both with the users that exist on the device (user name
and password) and via a RADIUS server.
The user is first searched for in the local database. If the user does not exist there, a
RADIUS request is sent.
The authentication must be handled via a RADIUS server.
A local authentication is performed only when the RADIUS server cannot be reached
in the network.