Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 2 has the following columns:
● Port
All available ports are displayed.
● Setting
Enable or disable the blocking of broadcast frames.
Steps in configuration
Enabling the blocking of broadcast frames for an individual port
1. Select the check box in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
Enabling the blocking of broadcast frames for all ports
1. In the "Setting" drop-down list in table 1, select the "Enabled" entry.
2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
234
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04