Advertisement

Configuring with Web Based Management
5.4 The "System" menu
● Value
Shows the MAC address or client ID of the client.
● IP Address
Specify the IPv4 address that will be assigned to the client. The IPv4 address must be
within the IPv4 address band.
Procedure
Creating static leases
1. Select a Pool ID.
2. Select the Client identification method.
3. Enter the value.
4. Click the "Create" button.
5. Specify the IPv4 address that will be assigned to the client.
6. Click the "Set Values" button.
Deleting static leases
1. Enable the "Select" check box in the row to be deleted.
Repeat this for all entries you want to delete.
2. Click the "Delete" button.
The entry is deleted.
5.4.9

SNMP

You should also refer to the chapter "Technical Basics", section "SNMP (Page 35)".
118
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04