Restart
Note the following points about restarting a device:
● You can only restart the device with administrator privileges.
● A device should only be restarted with the buttons of this menu or with the appropriate
CLI commands and not by a power cycle on the device.
● If the device is in "Trial" mode, configuration modifications must be saved manually
before a restart. Any modifications you have made only become active on the device after
clicking the "Set values" button on the relevant WBM page.
● If the device is in "Automatic Save" mode, the last changes are saved automatically
before a restart.
Reset to Factory Defaults
By resetting all the settings to the factory settings, the IP address and the passwords are
also lost. Following this, the device can only be accessed via the serial interface, using the
Primary Setup Tool or using DHCP.
NOTICE
With the appropriate attachment, a previously correctly configured device can cause
circulating frames after the reset and therefore the failure of the data traffic.
Resetting to defaults (profiles)
The profiles provide a preconfiguration for various use cases of the devices.
When you start a device with the default settings of a profile, the settings are reset to the
factory settings and some parameters are set so that they are designed for a certain use
case. In contrast to resetting to the factory settings. the users and passwords are retained
after the restart. The configured IP address is lost so that device can then only be accessed
via the serial interface, using the Primary Setup Tool or using DHCP.
NOTICE
With the appropriate attachment, a previously correctly configured device can cause
circulating frames after the reset and therefore the failure of the data traffic.
Which settings were set specially for a profile are displayed before the restart.
The profiles can be used independently of the factory setting of the device.