This page shows the temperature values of internal and external modules of the device. The
modules are only shown if they make temperature information available. If you add or
remove a module, the display is automatically adapted.
If the temperature value falls below or exceeds the displayed threshold values, the status
changes accordingly.
On the "System > Events > Configuration" page, you can specify how the device signals the
status change.
Description
● Name
Shows the name of the module.
The information in the row "Enclosure" or "Chassis" relates to the inner temperature of
the housing.
● Status
Depending on the relationship between the threshold values and the current temperature
the following status values are displayed in ascending priority.
– OK
– WARNING
– CRITICAL
– INVALID
– INITIAL
● Temperature [°C]
Shows the current value of the temperature. The display is updated at regular intervals.
The value can have a tolerance of +/- 3 °C
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04
The temperature value is within the preset threshold values.
The lower or upper threshold value of the severity level "Warning" was exceeded.
The lower or upper threshold value of the severity level "Critical" was exceeded.
The value could not be read out or is invalid. In the "Temperature [°C]" box "-" is
displayed.
No data has been read out yet. "-" is displayed in all boxes.
Configuring with Web Based Management
5.3 The "Information" menu
79