Siemens SCALANCE XB-200 Configuration Manual page 70

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
● Entries
Maximum number of samples that can be saved at the same time.
● Interval [s]
Interval after which the current status of the statistics will be saved as a sample.
The table has the following columns:
● Sample
Number of the sample
● Sample Time
System up time at which the sample was taken.
● Unicast
Number of received unicast frames.
● Multicast
Number of received multicast frames.
● Broadcast
Number of received broadcast frames.
● CRC
Number of frames with a bad CRC checksum.
● Undersize
Number of frames that are shorter than 64 bytes.
● Oversize
Number of frames discarded because they were too long.
● Fragments
Number of frames that are shorter than 64 bytes and have a bad CRC checksum.
● Jabbers
Number of frames with a VLAN tag that have a bad CRC checksum and will be discarded
because they are too long.
● Collisions
Number of collisions of received frames.
● Utilization [%]
Utilization of the port during a sample.
70
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04