Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– "-" (disabled)
– Up
– Down
– No Change: The setting in table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Setting
Select the setting from the drop-down list. You have the following options:
– Up
– Down
– "-" (disabled)
Steps in configuration
Configure error monitoring for a port
1. From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2. Click the "Set Values" button.
Configure error monitoring for all ports
1. Select the required setting from the drop-down list of the "Setting"column.
2. Click the "Copy to table" button. The setting is adopted for all ports of table 2.
3. Click the "Set Values" button.
152
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
The error handling is not triggered.
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04