Configuring with Web Based Management
5.4 The "System" menu
● Trap
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
● Log Table
The device writes an entry in the event log table, see "Information > Log Table"
● Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
● Faults
The device triggers an error. The error LED lights up
Steps in configuration
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
– E-mail
– Trap
– Log Table
– Syslog
– Faults
2. Click the "Set Values" button.
5.4.6.2
Severity Filters
Setting the Severity Filters
On this page, set the threshold levels for sending system event notifications.