Severity Filters - Siemens SCALANCE XB-200 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.4 The "System" menu
● Trap
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
● Log Table
The device writes an entry in the event log table, see "Information > Log Table"
● Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
● Faults
The device triggers an error. The error LED lights up
Steps in configuration
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
– E-mail
– Trap
– Log Table
– Syslog
– Faults
2. Click the "Set Values" button.
5.4.6.2

Severity Filters

Setting the Severity Filters
On this page, set the threshold levels for sending system event notifications.
104
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xc-200Scalance xp-200

Table of Contents