5.4.9.2

Traps

SNMP traps for alarm events
If an alarm event occurs, the device can send SNMP traps (alarm frames) to up to ten
different management stations at the same time. Traps are only sent if the events specified
in the "System > Events" menu occur.
Note
Traps are only sent if you have enabled the option "SNMPv1 Traps" in the "General" tab or
in "System > Configuration".
Description
● Trap Receiver Address
Enter the IP address of the station to which the device sends SNMP traps. You can
specify up to ten different recipients servers.
The table has the following columns:
● Select
Select the row you want to delete.
● Trap Receiver Address
If necessary, change the IP addresses of the stations.
● Trap
Enable or disable the sending of traps. Stations that are entered but not activated do not
receive SNMP traps.
Procedure
Creating a trap entry
1. In "Trap Receiver Address", enter the IP address of the station to which the device will
send traps.
2. Click the "Create" button to create a new trap entry.
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04
Configuring with Web Based Management
5.4 The "System" menu
121