Table 2 has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Setting
From the drop-down list, select whether the port should block or forward outgoing DCP
frames. You have the following options available:
– Forward
– Block
Steps in configuration
1. From the options in the drop-down list in the row, select which ports should support
sending DCP frames.
2. Click the "Set Values" button.
5.5.12

LLDP

Identifying the network topology
LLDP (Link Layer Discovery Protocol) is defined in the IEEE 802.1AB standard.
LLDP is a method used to discover the network topology. Network components exchange
information with their neighbor devices using LLDP.
Network components that support LLDP have an LLDP agent. The LLDP agent sends
information about itself and receives information from connected devices at periodic
intervals. The received information is stored on the device.
SCALANCE XB-200/XC-200/XP-200 Web Based Management

Configuration Manual, 07/2016, C79000-G8976-C360-04

DCP frames are forwarded via this port.
No outgoing DCP frames are forwarded via this port. It is nevertheless still possible to
receive via this port.
Configuring with Web Based Management
5.5 The "Layer 2" menu