● Bridge Priority
Enter the bridge priority in this box. The value for the bridge priority is a whole multiple of
4096 with a range of values from 0 to 61440.
● VLAN ID
Enter the VLAN ID. Here, you can also specify ranges with Start ID, "-", End ID. Several
ranges or IDs are separated by ",".
Permitted values: 1- 4094
Procedure
Creating a new entry
1. Enter the number of the MSTP instance in the "MSTP Instance ID" box.
2. Click the "Create" button.
3. Enter the ID of the VLAN in the "VLAN ID" box.
4. Enter the priority of the bridge in the "Bridge Priority" box.
5. Click the "Set Values" button.
Deleting entries
1. Use the check box at the beginning of the relevant row to select the entries to be deleted.
2. Click the "Delete" button to delete the selected entries from memory. The entries are
deleted from the memory of the device and the display on this page is updated.
5.5.8.5

MST Port

Configuration of the Multiple Spanning Tree port parameters
On this page, you set the parameters for the ports of the configured multiple spanning tree
instances.
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04
Configuring with Web Based Management
5.5 The "Layer 2" menu
205