3.18.6.1 KEYS

This menu is obtained by pressing the KEYS softkey in the SETUP menu.
Configuration of the spinwheel functions and the key characteristics. The selection is made with SEL,
the spinwheel and the editor (number block).
ROLLKEY configuration
PROGRESSION
INCR VALUE
KEYS configuration
KEYCLICK
SAVE KEY
Configuring the SAVE key to NEXT FREE + ACT is very useful when it comes to save frequencies
found with F-SCAN or D-SCAN to the memory with just one key stroke. These frequencies can then be
further observed by using the M-SCAN.
4052.2000.02
Progression factor of frequency setting by spinwheel
OFF, STEP1 to STEP9
Any increment which is added to or subtracted from the receiving frequency if
there is a rollkey pulse.
0.001 to 1000 kHz
For SSB modulation (CW, LSB and USB) an increment value of 1 Hz is always
automatically set.
Setting the key click
OFF, SOUND1 QUIET, SOUND1 LOUD, SOUND2 QUIET, SOUND2 LOUD,
SOUND3 QUIET, SOUND3 LOUD,
Determines the function of the SAVE key
CURRENT MEM
CURRENT MEM + ACT Like CURRENT MEM, additionally the memory location
NEXT FREE
NEXT FREE + ACT
The receiver parameters will be stored in the current
memory location
will be set for an MSCAN query (ACTivate)
The receiver parameters will be stored in the next free
memory location
Like NEXT FREE, additionally the memory location will
be set for an MSCAN query