Trigger Subsystem - R&S EB200 Manual

Miniport receiver
Table of Contents

Advertisement

EB200 Manual

4.5.19 TRIGger subsystem

The trigger subsystem is used to synchronize actions within the unit with events.
With SW option EB200CM (Coverage Measurement) triggered level measurements can be carried out.
The trigger source is selected by using command TRIGer:SOURce EXTernal|INTernal|TIMer .
See also Annex G (Coverage Measurement).
TRIGger[:SEQuence]
.
:SLOPe POSitive|NEGative
Setting of the slope initiating a trigger via rear-panel connector X8, pin 12 in FASTlevcw and LIST
modes
Parameters:
POSitive
NEGative
*RST state:
POSitive
Example:
TRIGger:SLOPe NEGative
.
:SLOPe?
Query of the slope initiating a trigger via rear-panel connector X8, pin 12 in FASTlevcw and LIST modes
Parameters:
none
Result:
NEG, POS
Example:
TRIGger:SLOPe? -> NEG
4052.2000.02
trigger at positive slope
trigger at negative slope
4.119